pc header -->
Email:info@bidragon.com
Whatsapp:+8613373703313
English
FAQ


Language:
electric-steam-boiler
electric-heating-steam-boiler

Electric Heating Steam Boiler

This electric heating steam generator is package boiler, with PLC control system and various protection function, easy to install and easy to operate, widely used in kitchen, sauna room, laundry room,etc.
Model: WDR
Rated Evaporation: 0.3-4T/h
Rated Steam Pressure: 0.7/1.0/1.25 Mpa
Rated Steam Temperature: 174/184/194℃
Designed Heat Efficiency: 98%
Social Media Home Page Links:
Introduction
Parameters
solution
recommend
Custom

Product Introduction

Structure features:
1). Heating tube built-in direct heating,
Touching water directly in order to increase heat transfer area.
Compact structure, small size, easy to install, maintain and replace.
This type electric steam generator shell adopts stainless steel, safety and reliable, long lifespan.
2). Electric heating type ensures heating efficiency up 98%, no pollution.
3). Uniform heating area, stable heating type, large evaporation area.
4). Various automatic protection functions: pressure controller, advanced program control, automatic , interlock, automatic alarm, which achieves automatic control. Our electric steam boiler has the automatic protection function of overheating, over-voltage, water shortages, short circuit, phase loss, leakage and so on, safe and reliable, easy to operate.
5). This electric steam generator is equipped with water level sensor, which has function of control the water level automatically, water level alarm, interlock.
6). High quality boiler element: all the selected electrical appliances meet the short-circuit conditions under the dynamic stability and thermal stability requirements, used to disconnect the short-circuit current of electrical appliances, to meet the short-circuit conditions under the off capacity.
7). Automatic pressure control: normally, the boiler pressure is below design pressure, when the boiler pressure is above the design pressure, the heating tube will stop heating and start alarm, and if the pressure continue to rise, the safety valve will open automatically and release pressure to ensure boiler safety.

Electric Heating Steam Boiler Technical Parameter

Model WDR0.3 WDR0.5 WDR1 WDR1.5 WDR2 WDR3 WDR4
Rated Evaporation t/h 0.3 0.5 1 1.5 2 3 4
Rated Steam Pressure Mpa 0.7/1.0/1.25
Rated Steam Temp. 174/184/194
Water Supply Temp. 20
Designed Heat Efficiency % 98 98 98 98 98 98 98
Power requirement   380V/50Hz
Electric heating pipe arrangement   Single-ended Both ends
Weight T 0.85 1.2 1.5 1.6 2.1 2.5 3.1
Boiler Operating Water Volume T 0.54 0.8 1.2 1.5 2 2.9 3.6
Boiler Full Water Volume T 0.64 1 1.5 2 2.7 3.5 4.5
Transportation Size L mm 1700 1950 2340 2840 2840 2840 2840
W 1400 1480 1520 1450 1650 1750 1950
H 1600 1680 1680 1680 1870 2010 2240
Installation Size L mm 32 32 40 40 40 40 40
W 40 50 80 80 100 100 100
H 40 40 40 40 50 50 50
Water Inlet DN mm 31 32 40 40 40 40 40
Main Steam Outlet DN mm 40 50 80 80 100 100 100
Manual Sewage Outlet DN mm 40 40 40 40 50 50 50
Safety Valve DN mm 32 40 2*40 2*40 2*40 2*40 2*50
Remark: The above parameters are for reference only. The technical parameters and supporting auxiliary machines are subject to the design drawings.

Similar Product Recommendations

Customize the editing section

Thermal Oil Boiler Indonesia Project Services

Thermal Oil Boiler Indonesia Project Services

Thermal Oil Boiler Indonesia Project Services

Thermal Oil Boiler Indonesia Project Services

+86 13373703313
info@bidragon.com

Get a free quote

We look forward to hearing from you and will respond within 24 hours!
X